EMC Laboratory
EMC testing covers both electromagnetic interference (EMI) and electromagnetic susceptibility (EMS). We are equipped with a 3m semi-anechoic chamber and shielded rooms, covering emission and immunity testing for automotive electronics, home appliances, industrial control and medical devices.
Testing capabilities
All items below are performed within our accreditation scope; specific methods follow the corresponding standards.
Main equipment
The equipment list and key parameters are published here so you can judge the boundaries of our capabilities.
| Equipment | Model / Brand | Key parameters / Use |
|---|---|---|
| 3m Semi-Anechoic Chamber | 966 anechoic chamber + absorbing materials + impedance grounding | Radiated emissions RE, radiated immunity RI |
| Shielded Room | Dedicated conducted testing environment | Conducted emissions CE, conducted immunity CI, BCI |
| EMI test receiver | R&S ESR7 / ESL3 | 9kHz~6GHz |
| Artificial mains network LISN | Schwarzbeck NNBM8124 | Conducted emissions voltage method |
| Full-band antenna set | Biconical / log-periodic / broadband horn | 0.15MHz~6GHz in four segments |
| BCI integrated test mainframe | NSG 4070C-0 | 10kHz~400MHz,60/100/150/200/300mA |
| Current injection probes | F-120-6A | Three positions: 15 / 45 / 75cm |
| High-power amplifiers | CBA 400M-110 / PA 5840-150 | Radiated immunity 25~600V/m |
| Automotive transient immunity system | NSG 5500 / EMS7637A | ISO 7637-2 / -3 |
| ESD generator | NSG-437 / EMS61000-2A | Air discharge 15kV / contact discharge 8kV |
| Harmonic and flicker analyzer | NSG1007 | IEC 61000-3-2 / -3-3 |
| Lightning surge / voltage dip / EFT burst combination tester | MODUL A6100 | Surge 4.4kV / EFT / voltage dips |
Equipment is calibrated and traceable on schedule; parameters are subject to on-site calibration certificates.
Standards covered
Other laboratory capabilities
Want to see the actual condition of the equipment?
Both our Shenzhen Bao'an and Dongguan Tangxia sites accept scheduled visits, and we will arrange engineers in the relevant field to receive you.